1. Automatic test function: the machine can self perfrom automatic scanning test for an internal return motion or circuit break inside the switchboard, to facilitate the maintenance/repair test motion to turn from complication into simplicity, and upgrade work performance and reliance of the mainframe.
2. Storage function: the return detection shall only go through confirmation of a fixed period of time prior to engagemement of alarm motion, to reduce the disturbance and error report situation of general circuits, and upgrade the reliability of the mainframe.
3. Reserved power protection device: under the condition of power suspension, the reserved power with a power release till below DC-18V, power discharge will be automatically stopped,to extend the battery service life.
4. Quality control: the parts used for the operation panel of the machine and internal base borad are all through CN squality recognition; the mainframe before ex-plant shall go through a strict test to ensure service function to be normal and without an error.
5. Humanistic design: the internal base boards are all in modular design; the external line output/input is separated by a terminal board; and due protection measures are provided to the input terminal. If an insitu wrong connection of external power into a return board, it is only required to replace the return board of the said return, without a need of dismantling external distributing circuits, to facilitate the maintenance / inspection performance to be upgraded considerably.
1. Power (AC): AC110V; 50/60Hz. 2. Reserved: power DC24V. 3. Charging voltage / current: DC26V; 450mA below. 4. Circuit Voltage / Current: DC24V short circuit voltage below 5V 32mA. 5. Return external circuit resistance: black & forth below50Ω. 6. Detector installation: differential type, fixed-temperature type smoke detector(DC24V 80uA) a smoke detector can be accessed for no more than 18 units each L. 7. Terminal resiatance: 10KΩ. 8. Quantity of indication: 1.3 times of the panel return. 9. Regional alarm quantity: 1.3 times of the panel return. 10. Material of machine frame: 1.6m/m-2.0m/mstandard material. 11. Main stereo: double noise above BUZZER; 92db. 12. Connection joint for transfer report: no voltage connector capacity AC150V7A. 13. Controller of an iron rolling door: generally applicable to 100V ~ 220V.
1. Automatic test function:Automatic scanning test of internal return.(Uperade work performance, time saving, labor saving.)
2. Storage function:Upgrade reliance, reduce wrong report ratio.(Avoid nonsense work hour consumption.)
3. Reserved Power protection: Upgrade battery life.
(Save maintenance/repair cost, battery consumption.)
4. Qualtity control: Upgrade reliability of mainframe.
(Reduce maintence cost,increase revenue.)
5. Humanistic design: Convenient for fabrication. (Upgrade work performance, time saving.)
6. Outlook design: Easy to understand the motion of the mainframe & return panel outlook is beautiful. (Easy to facilitate a user to operate.)
7. Simple circuit layout: Apply 2 units of super large type circuit slot, to ensure easy circuit layout. (Save circuit trimming time, labor saving.)