1. Coil data heat sink: 80 x 80 x 3mm (aluminum)
2. Duty cycle(%)= X 100% continuous.
3. (100%) Or less.
4. (50%) Or less.
5. (25%) Or less.
6. (10%).
7. MAX. "on" time in seconds: 230, 25, 6.
8. Watts at 20℃: 7, 14, 28, 70.
9. Ampere-turns at 20℃: 855, 1200, 1700, 2700.
Plunger weight: 20g / total weight: 82g.