The GT series grid-connected Photovoltaic Inverter is delivered in a waterproof IP65 enclosure which can be installed in either a grid connected solar tracker system or a stationary PV system. By taking care of an accurate power conversion from solar panel to local grid, the GT series effects conversion process with minimal power loss and maximum reliability.
Specifications:
Model Item | PM-2000GT | |
Inverter Technology | Conversion Mode | Sine-wave, Current source, High frequency PWM |
Isolation Method | Transformer-less Design * | |
DC Input Data | ||
Nominal DC Voltage | 360 VDC | |
Max. DC input Voltage | 500 VDC | |
Working range | 120VDC~500VDC ** | |
Max DC input current (Each MPPT Tracker) | 14.6 Amp | |
MPPT Range | 150 VDC ~ 450 VDC | |
MPPT Tracker | 1 | |
AC Output Data | ||
Nominal AC Power | 2000 | |
Max. AC Power | 2200 | |
Nominal AC Voltage | AC 230V | |
Output Connect Method | 1-Phase / 2-Wires(L, N, G) or 1-Phase / 3-Wires(L1, L2, G) | |
AC Voltage Rang | 184~264.5Vac(Base on 230 Vac) | |
Nominal AC Current | 8.7Amp | |
Frequency | 50/60Hz Auto-Selection (47.5 ~ 50.2 Hz or 59.3 ~ 60.5 Hz) | |
Power Factor | >0.99 with nominal AC current | |
Current Distortion | Total Harmonic current : Less than 5% Single Harmonic current : Less than 3% | |
Efficiency Data | ||
Max. efficiency | >96% | |
Euro efficiency | >94% | |
CEC efficiency | >94% | |
Environmental | ||
Operating Temperature | -25 °C ~ + 50 °C | |
-13 °F ~ 122 °F | ||
Humidity | 0 to 90%(Without condensation) | |
Altitude | 0 ~ 2000 M / 0 ~ 6600 ft | |
Mechanical | ||
Dimensions (H x W x D in mm ) | 455 x 430 x 170 | |
Weight (Kgs / Lbs) | 23 / 51 | |
Protection Class | IP65, outdoor | |
Cooling | Free Convection | |
AC Connector | Terminal | |
DC Connector | Multi-Contact | |
Communication | ||
Communication Interface | Standard | |
Optional | ||
Front Panel | ||
LCD | Boost input Voltage/Boost input Current/Boost input Power/AC output Voltage /AC output frequency/AC output current /AC output power/AC Energy yield/Inner Temperature/Heat sink Temperature /Status message/ Error message | |
LED | RED | |
Yellow | ||
Green | ||
Key Pad | UP key/ Down key/ Function key/ Enter key | |
Protection | ||
Utility | Over/under Voltage, Over/under Frequency, Ground fault, DC Isolation fault | |
Islanding operation detection | Passive : Voltage phase jump detection Active : Reactive power control | |
Over Temperature | reduced output power | |
Certification | ||
Safety | Europe | |
North American | ||
EMI/EMC | EN 6 1000-6-1 , EN 6 1000-6-2 , EN 6 1000-6-3 , EN 6 1000-6-4 |