*Optimal Wind Maximum Power Point Tracking
*Wind & Solar Charge Controller
*Can be paralleled (Max. 16 sets) at will; according to your demand.
*Battery charge management; state of charge infromation.
*Built-in Battery Energy Monitor tracks Power production and consumption to calculate the energy remaining in battery state of charge (SOC) is displayed in percent full; Amp-hours; Watt-hours; and 90days of energy-harvest history is stored in the wind charger.
*Continuous output Power Rating without de-rating at up to 50°C ambient temperature.
*Supports Flooded Lead Acid (FLA); GEL; and Absorbed Glass Mat (AGM) batteries; 2/3/4 Stage charging with adjustable set point.
*Input acceptance up to 220VAC or 240VDC normal (240VDC Max).
*Built-in temperature compensation function for safe and complete charging.
MODEL | PM-WCC-100AM-1248 |
ELECTRICAL | |
Input Voltage Range (no damage) | 0 ~ 220 VAC |
Operating Input Voltage Range from PMG (Permanent Magnet Generator) | 20 ~ 220 VAC 0 ~ 600 Hz |
Optimal Range: 20 ~ 180 VAC | |
System voltage ratings | 12; 24; 36; 48 VDC |
Current ratings-Battery Charge Control | 100A |
Max. Current in the Brake Resistor | 100A Diversion load |
DC Input Voltage Range | 16 ~ 240 VDC Operating |
240 VDC Maximum | |
Automatic Brake Function | 5 Level: 200; 210; 220; 230; 240 VDC (Adjustable) Can be customized for the wind turbines |
Maximum Wind Turbine Capacity | |
Charging 48 VDC Batteries | 6.0KW |
Charging 36 VDC Batteries | 4.5KW |
Charging 24 VDC Batteries | 3.0KW |
Charging 12 VDC Batteries | 1.5KW |
Charge Regulation Modes | Bulk; Absorption; Float; Auto/ Manual Equalization |
Battery Temperature Compensation | 5.0 mV per °C ; per 2 volt cell |
DC to DC Conversion Capability | 12V Battery: 16~240VDC |
24V Battery: 32~240VDC | |
36V Battery: 48~240VDC | |
48V Battery: 64~240VDC | |
Display Status | Built-in 2-line; 20-character LCD with backlight LCD status screen displays input voltage and current; output voltage and current; charge-mode; Battery SOC |
Data Logging | Logs energy harvested for 90 days; LCD displays WH; KWH; AH |
Energy Monitor | LCD shows SOC; AH; WH; and present charge or discharge current. A 50mV/ 500Amp shunt is required to use |
Auxiliary Relays | Two independent relays with from A (SPST) contacts for control of external devices. Contact rating is 3 Amps; 50VDC |
Operation Temperature | Full Power Output to +50 °C ambient |
Standby Power | < 2 Watts |
Relative Humidity | 0 ~ 100% condensing |
MECHANICAL | |
Dimensions (mm) [H x W x L] | 401 x 258 x 183 |
Weight | 8.3 kg |
Optional Diversion Load | |
Specifications subject to change without notice |