MPPT Wind Charge Controller

MPPT-Wind-Charge-Controller

  • Model No: PM-WCC-100AM-1248
  • Factory Location: Taiwan
  • Sample Request: No
  • Target Markets: Worldwide

Detail Information

Description :

*Optimal Wind Maximum Power Point Tracking
*Wind & Solar Charge Controller
*Can be paralleled (Max. 16 sets) at will; according to your demand.
*Battery charge management; state of charge infromation.
*Built-in Battery Energy Monitor tracks Power production and consumption to calculate the energy remaining in battery state of charge (SOC) is displayed in percent full; Amp-hours; Watt-hours; and 90days of energy-harvest history is stored in the wind charger.
*Continuous output Power Rating without de-rating at up to 50°C ambient temperature.
*Supports Flooded Lead Acid (FLA); GEL; and Absorbed Glass Mat (AGM) batteries; 2/3/4 Stage charging with adjustable set point.
*Input acceptance up to 220VAC or 240VDC normal (240VDC Max).
*Built-in temperature compensation function for safe and complete charging.

Specification :

  MODELPM-WCC-100AM-1248
  ELECTRICAL
  Input Voltage Range (no damage)0 ~ 220 VAC
  Operating Input Voltage Range from PMG
  (Permanent Magnet Generator)
20 ~ 220 VAC
0 ~ 600 Hz
Optimal Range: 20 ~ 180 VAC
  System voltage ratings12; 24; 36; 48 VDC
  Current ratings-Battery Charge Control100A
  Max. Current in the Brake Resistor100A
Diversion load
  DC Input Voltage Range16 ~ 240 VDC Operating
240 VDC Maximum
  Automatic Brake Function5 Level:
200; 210; 220; 230; 240 VDC
(Adjustable)
Can be customized for the wind turbines
  Maximum Wind Turbine Capacity
Charging 48 VDC Batteries6.0KW
Charging 36 VDC Batteries4.5KW
Charging 24 VDC Batteries3.0KW
Charging 12 VDC Batteries1.5KW
  Charge Regulation ModesBulk; Absorption; Float; Auto/ Manual Equalization
  Battery Temperature Compensation5.0 mV per °C ; per 2 volt cell
  DC to DC Conversion Capability12V Battery: 16~240VDC
24V Battery: 32~240VDC
36V Battery: 48~240VDC
48V Battery: 64~240VDC
  Display StatusBuilt-in 2-line; 20-character LCD with backlight
LCD status screen displays input voltage and
current; output voltage and current; charge-mode;
Battery SOC
  Data LoggingLogs energy harvested for 90 days; LCD displays WH; KWH; AH
  Energy MonitorLCD shows SOC; AH; WH; and present charge or discharge current. A 50mV/ 500Amp shunt is required to use
  Auxiliary RelaysTwo independent relays with from A (SPST) contacts for control of external devices. Contact rating is 3 Amps; 50VDC
  Operation TemperatureFull Power Output to +50 °C ambient
  Standby Power< 2 Watts
  Relative Humidity0 ~ 100% condensing
  MECHANICAL
  Dimensions (mm) [H x W x L]401 x 258 x 183
  Weight8.3 kg
  Optional Diversion Load 
  Specifications subject to change without notice

Power Master Technology Co., Ltd.

  • Taiwan