Ji-Shen Electronic Co., Ltd.

Taiwan Manufacturers, Exporters.

Products

UPS Power Back-Up Supply

UPS-Power-Back-Up-Supply

  • Model No: A2D、A4D Series
  • Factory Location: Taiwan
  • Sample Request: No
  • Target Markets: Worldwide

Detail Information

Description :

1. All-directional battery auto management system prolongs battery life.
2. The system is equipped with city electricity and EPS power, and has an electronic protection device for short-circuit and overload. The system’s reaction is so quick that the electric rolling door can be properly protected.
3. A variety of time sequences, sound warnings and lamp signals are available. All the important information, such as the supply time of city electricity, the time during power failure, the number of power failure times, battery low voltage, overload and short circuit will be automatically recorded in the water for access and trouble analysis.
4. Under static status, the electronic board won’t consume power, and can be stored for one year
5. When power failure happens, you can use the remote controller to coordinate with the lock auto clear function for evacuation. The remote controller must be close-loop designed.
6. The output control adopts the power consuming mode of inducing motor. The start current is small. The noise is low, and the torsion is big.
7. Intellectual discrimination: when power failure happens, EPS of electric rolling door or window will boost output voltage synchronically. After the action is completed, EPS has no load, and automatically resumes to low voltage, power-saving standby status. The standby time lasts for 2-4 days.
8. It is impact, light-weighted, pretty and dignified. The installment is easy.

Specification :

ModelA2DA4DRemark
Fuse15A15A 
AC InputVoltage230V +/- 15%UPS will automatically indentify AC Input frequency : 50Hz or 60Hz and set up as power outage output frequency
Frequency50/60HZ +/- 5%
Recharging Average Consumption Power17W/max.
Power Outage Output Frenquency50/60HZ +/- 1%
Power Outage Output VoltageStandby140V +/- 15% (Energy Saving Mode)Output Voltage is adjustable by switch from panel
In running220V +/- 10%
Standby Consumption Power < 1W 
Battery Included24V/4.5/5 AH24V/7.0/7.2 AHValve Regulated Lead - Acid Battery
UPS Standby time (New battery)48 hrs96hrsWith remote control, it depends on power consumption of remote control
Apply to MotorSpecification6P 1/2HP below 400kgs6P 1/2HP below 700kgs 
 Starting CurrentWithin 8AWithin 10A 
 Working CurrentWithin 2.7AWithin 3.7A 

Related Prodcuts

Ji-Shen Electronic Co., Ltd.

  • Taiwan