100% made in Taiwan it allows switching to UPS supply automatically when external power supply is off or abnormal over high or low voltage. It contains two steps AVR. Voltage regulation plus UPS provide quasi sine wave output offered lightening surge protection, noise filtering and short circuit protection for PC and servo and other small capacity IT equipment.
Model | NS-A601 | NS-A102 | B-152 | B-202 | B-302 | |||||||||||||||||||||
Capacity VA/Watts | 600VA/360W | 1000VA/600W | 1500VA/900W | 2000VA/1200W | 3000VA/1800W | |||||||||||||||||||||
Input | Voltage | 110/115/120VAC or 220/230/240VAC | ||||||||||||||||||||||||
Voltage Range | 83VAC~143VAC or 166VAC~286VAC | |||||||||||||||||||||||||
Frequency | 47Hz~53Hz or 57Hz~63Hz | |||||||||||||||||||||||||
Output | Voltage | 110/115/120VAC or 220/230/240VAC±10% | ||||||||||||||||||||||||
Frequency | 50Hz or 60Hz±1Hz | |||||||||||||||||||||||||
Waveform | Simulated sine wave | |||||||||||||||||||||||||
Transfer Time | <4ms | |||||||||||||||||||||||||
Outlets | NEMA5-15R*2pcs or the other type | NEMA5-15R*6pcs or the other type | ||||||||||||||||||||||||
Battery | Battery Voltage | 12V DC | 24V DC | 48V DC | ||||||||||||||||||||||
Battery Type | High Rating 12V/5AH | 12V/4AH | High Rating 12V/5AH | High Rating 12V/9AH | ||||||||||||||||||||||
Battery Quantity | 1 PCS | 2 PCS | 4 PCS | |||||||||||||||||||||||
Back up Time (Load with 1 PC) | 15 mins | 40 mins | 60 mins | 90 mins | 120 mins | |||||||||||||||||||||
Recharging Time | 8 hours to 90% after fully discharged | |||||||||||||||||||||||||
Function | Line Conditioning Regulation(AVR) | When input voltage too high or too low, it’s with rising or decreasing voltage function automatically | ||||||||||||||||||||||||
LED Display | 1 LED: Normal (steady on) Discharging (slow blinking) Battery low (quick blinking) Overload/Short/UPS Cut-off (LED off) | 10LEDs: Normal (Green) Discharging (Green) AVR on (Orange) UPS cut-off (Orange) Overheat (Red) Battery level (5LEDs) | ||||||||||||||||||||||||
Alarm | Buzzer on for Back-up mode, Battery low | |||||||||||||||||||||||||
Mute Switch | No | Yes (can be switched) | ||||||||||||||||||||||||
DC Start(Cold start) | While mains black out, it can use internal batteries to turn on the UPS | |||||||||||||||||||||||||
Auto Restart UPS | While mains recover, it can turn on automatically | |||||||||||||||||||||||||
Output Auto Delay | No | Yes (delay 5 seconds) | ||||||||||||||||||||||||
Overload/Short Protection | Circuit Breaker(Line mode), Fuse and Electronic Circuit (back-up mode) | |||||||||||||||||||||||||
Lightning/Surge Protection | 350J/10000A | |||||||||||||||||||||||||
Communication Port | Dry Contact (it can be matched with RUPS-2000 software for windows 95/98/NT/2000/ME/XP/Vista) | |||||||||||||||||||||||||
UPS For Elevator | No | Yes (with huge starting current ability, 5 seconds delayed to send output, dry contact function. All cable connection are using terminal block) | ||||||||||||||||||||||||
Safety Conformance | EN62040-1-1 | |||||||||||||||||||||||||
EN62040-2 | ||||||||||||||||||||||||||
Environment | Temperature | 0℃~40℃ | ||||||||||||||||||||||||
Humidity | 0%~95% (non-condensing) | |||||||||||||||||||||||||
Audible Noise | ||||||||||||||||||||||||||
Physical | Net weight (KGS) | 6.5 | 11.5 | 17.6 | 18.5 | UPS:14 Battery Bank:14 | ||||||||||||||||||||
Dimension:WxHxD (cm) | 9.4x17x27 | 9.4x17x39 | 16x24x41 | 16x24x41 (2 sets) |