Specially for CNC and industrial equipment
More than 25 years design and manufacturing experience, specialized R & D team and stringent quality control ensured top-rated product. Specialized in the manufacturing of all kinds of transformer, single phase and 3 phase transformer, auto transformer, automatic voltage regulator and UPS specific transformer, inductor and choke coil. We can also accept custom order design and manufactured to different capacity and specification.
Model No. (TD & MTF-) & Capacity | Single Phase Series | Three Phase Series |
1003/3KVA 1025/25KVA 1005/5KVA 1030/30KVA 1007/7.5KVA 1040/40KVA 1010/10KVA 1050/50KVA 1015/15KVA 1060/60KVA 1020/20KVA 1075/75KVA | 3005/5KVA 3045/45KVA 3180/180KVA 3007/7.5KVA 3050/50KVA 3200/200KVA 3010/10KVA 3060/60KVA 3250/250KVA 3015/15KVA 3075/75KVA 3300/300KVA 3020/20KVA 3100/100KVA 3400/400KVA 3030/30KVA 3120/120KVA 3500/500KVA 3040/40KVA 3150/150KVA | |
Voltage | CS: Isolated Type I / P: 1ψ 2W 220V O/ P: 1ψ 2W 110V or 110/220V or 1ψ 3W 110-0-110V C5: Isolated Type I / P: 1ψ 2W O/P:1ψ 2W Special specification and voltage C0: Auto Type I / P: 1ψ 2W O/P:1ψ 2W Special specification and voltage | Y: Auto Type I / P: 3ψ 3W 380V O/P : 3ψ 3W 220V or 200V Y0: Auto Type I / P: 3ψ O/P:3ψ Special specification and voltage Y2: Isolated Type I / P: 3ψ 3W O/P:3ψ 4W Y5: Isolated Type I / P: 3ψ 3W O/P:3ψ 4W Special specification and voltage |
Frequency | 50/60Hz | |
Insulation Class | Class A (105℃) Class B (130℃) Class F (155℃) Class H (180℃) | |
Cooling Method | Dry type with cooling fan | |
Noise | <60db | |
Efficiency | >97% | |
Insulation Resistance | P-SE, S-PE >DC500V/500MΩ | |
Hi-Pot Test | P-SE,S-PE AC3KV/60SEC 5mA | |
Hi-Frequency Test | 2 times of nominal voltage 400Hz/18SEC | |
Impedance | 2~5% 50/60Hz | |
Protection | IP20 | |
Environment | Temperature: 0℃~50℃ Humidity: 20%~95% (non-condensing) | |
Safety Regulation | CE EN61558-1:1997 and EN61558-2-4:1997 |
1. Scientifically reasonable design allowing control of voltage change rate within 1% - 1.5% range
2. Manufactured of brand new silicone steel sheet of Shin Nippon, Kawasaki, Japan that effectively reduces iron loss, reducing field inrush current and increase efficiency
3. Made of imported high purity copper wire that minimizes own loss rate and greatly increase effectiveness
4. Adopt AROMA, Japan improved A type and DOPONT Nomex insulating paper as the main insulating materials and enhanced ventilation and heat sink design to increase the high voltage resisting strength and insulation class and therefore extend the service life.
5. High efficiency design for more than 97% that effectively reduce stray capacity, leak impedance and inhibit input end noise
6. Patented appearance design gives elegant and modern look; high power density, compact size and increase space utilization
7. Adopted K coefficient in measuring harmonic wave ability; specially designed isolated transformer in filtering off tertiary harmonic wave and multiple output isolated transformer filters off 5, 7,17 and 19 X frequency harmonic wave (Optional)