1. Protection function of electronic starter:
(1) Over-current protection.
(2) No-load protection.(Power consumption at no-load is less than 1W)
(3) A florescent tube malfunction protection.
2. Safety requirement and reliability based:
(1) Life:
(a) Definition: the Electronic Starter fail to lid the lamp indicate the end of life.
(2) Testing condition of life durability:
(a) Normal temperature test:25℃,test input voltage AC 110V~AC 220V,continue light for 50000Hrs.
(b) Low temperature test:0℃,test input voltage AC 110V~AC 220V,continue light for 360Hrs.
(c) High temperature test:80℃,test input voltage AC 110V~AC 220V,continue light for 360Hrs.
(d) Lid test:25℃,test input voltage AC 110V~AC 220V,apply 10000 cycle for 25sec on,35sec off/cycle(Note: replace the failed lamp tube and continue the test again in case of break down of lamp tube).
3. Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃、25%~95%RH.
(2) Belong to indoor stabilizer.
1. Input voltage(V):AC 110V-220V.
2. Power frequency:50 / 60 Hz.
3. Input power(W):22.0 / 36.0 W.
4. Input current(A):0.1 ~ 0.2 / 0.16 ~0.33 A.
5. Power factor:99%.
6. Applicable lamp tube: T 8 – 10 / 16 W.