1. Protection function of electronic starter:
(1) Over-current protection.
(2) No-load protection.(power consumption at no-load is less than 1W).
(3) A florescent tube malfunction protection.
2.safety requirement and reliability based:
(1)Definition: the electronic starter fail to lid the lamp indicate the end of life.
3. Testing condition of life durability:
(1) Normal temperature test: 25℃, test input voltage AC 110V~AC 220V, continue light for 50000 hrs.
(2) Low temperature test: 0℃, test input voltage AC 110V~AC 220V, continue light for 360 hrs.
(3) High temperature test: 80℃, test input voltage AC 110V~AC 220V, continue light for 360 hrs.
(4)Lid test: 25℃, test input voltage AC 110V~AC 220V, apply 10000 cycle for 25 sec on, 35 sec off/cycle (note: replacethe failed lamp tube and continue the test again in case of break down of lamp tube).
4. Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃, 25%~95% RH.
(2) Belong to indoor stabilizer.
1. Input voltage(V): AC 1 1 0 V ~ 2 2 0 V.
2. Power frequency: 50 / 60 Hz.
3. Input power(W): 63.0 W.
4. Input current(A): 0.3 ~ 0.6 A.
5. Power factor: 98%.
6. Applicable lamp tube: T 8 –5 8 W.
7. (T8/T9 light tube suitable).