1. Eletro-hydraulic controls.
2. Without proportional pilot relief valve.
Model No. / Description | EFBG-03-125- -17 | EFBG-06-250- -17 | EFBG-10-500- -17 | ||||
Max. Operating Pressure MPa (PSI) | 24.5 (3550) | 24.5 (3550) | 24.5 (3550) | ||||
Max. Flow L/min (U.S.GPM) | 125 (33) | 250 (66) | 500 (132) | ||||
Metred Flow Adjustment Range L/min (U.S.GPM) | 1-125 (.26-33) | 2.5-250 (.66-66) | 5-500 (1.32-132) | ||||
Flow Controls | Rated Current | 600 mA | 580 mA | 700 mA | |||
Coil Resistance | 43.5 Ω | 43.5 Ω | 43.5 Ω | ||||
Differential Pressure MPa. (PSI) | 0.6 (85) | 0.7 (100) | 0.9 (130) | ||||
Hy steresis | Less than 7% | Less than 7% | Less than 7% | ||||
Repeatability | Less than 1% | Less than 1% | Less than 1% | ||||
Pressure Controls | Pres. Adj. Range MPa. (PSI) | C: | 1.4-13.7 (205-2000) | C: | 1.5-13.7 (220-2000) | C: | 1.6-13.7 (230-2000) |
H: | 1.4-20.6 (205-3000) | H: | 1.5-20.6 (220-3000) | H: | 1.6-20.6 (230-3000) | ||
Rated Current | C: | 750 mA | C: | 690 mA | C: | 690 mA | |
H: | 750 mA | H: | 730 mA | H: | 690 mA | ||
Coil Resistance | 10Ω | 10Ω | 10Ω | ||||
Hy stersis | Less than 3% | Less than 3% | Less than 3% | ||||
Repeatability | Less than 1% | Less than 1% | Less than 1% |