1. Protection function of electronic starter:
(1) Over-current protection.
(2) No-load protection.(Power consumption at no-load is less than 1W)
(3) A florescent tube malfunction protection.
2. Safety requirement and reliability based:
(1) Life:
(a) Definition: the Electronic Starter fail to lid the lamp indicate the end of life.
(2) Testing condition of life durability:
(a) Normal temperature test: 25℃,test input voltage AC 220V~AC 240V, continue light for 50000Hrs.
(b) Low temperature test: 0℃,test input voltage AC 220V~AC 240V, continue light for 360Hrs.
(c) High temperature test: 80℃, test input voltage AC 220V~AC 240V,continue light for 360Hrs.
(d) Lid test: 25℃, test input voltage AC 220V~AC 240V, apply 10000 cycle for 25sec on, 35sec off/cycle(Note: replace the failed lamp tube and continue the test again in case of break down of lamp tube).
3. Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃、25%~95%RH.
(2) Belong to indoor stabilizer.
1. Input voltage(V): AC 220V-240V.
2. Power frequency: 50 / 60 Hz.
3. Input power(W): 72.0W.
4. Input current(A): 0.32A.
5. Power factor: 99%.
6. Applicable lamp tube: T 8 – 3 6 W.