1.Protection function of Electronic Starter:
(1) Over-current protection.
(2) No-load protection (power consumption at no-load is less than 1W).
(3) A florescent tube malfunction protection.
2.Safety requirement and reliability based:
(1)Life:
(a) Definition: the Electronic Starter fail to lid the lamp indicate the end of life.
(2)Testing condition of life durability:
(a) Normal temperature test: 25℃, test input voltage AC 110V, continue light for 50000Hrs.
(b) Low temperature test: 0℃, test input voltage AC 110V, continue light for 360Hrs.
(c )High temperature test: 80℃, test input voltage AC 110V, continue light for 360Hrs.
(d) Lid test:25℃,test input voltage AC 110V,apply 10000 cycle for 25sec on,35sec off/cycle(Note: replace the failed lamp tube and continue the test again in case of break down of lamp tube).
3.Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃, 25%~95%RH.
(2) Belong to indoor stabilizer.
1.Input voltage(V): AC 1 1 0 V.
2.Power frequency: 50 / 60 Hz.
3.Input power(W): 40.0 W.
4.Input current(A): 0.35A.
5.Power factor: 99%.
6.Applicable lamp tube: T 8 – 2 0 W.