1. Protection function of electronic starter:
(1) Over-current protection.
(2) No-load protection.(Power consumption at no-load is less than 1W).
(3) A florescent tube malfunction protection.
2. Safety requirement and reliability based:
(1) Life
(a) Definition: the Electronic Starter fail to lid the lamp indicate the end of life.
(2) Testing condition of life durability:
(a) Normal temperature test: 25℃, test input voltage AC 110V, continue light for 50000Hrs.
(b) Low temperature test: 0℃, test input voltage AC 110V, continue light for 360Hrs.
(c) High temperature test: 80℃, test input voltage AC 110V, continue light for 360Hrs.
(d) Lid test: 25℃, test input voltage AC 110V,apply 10000 cycle for 25sec on,35sec off/cycle(Note: replace the failed lamp tube and continue the test again in case of break down of lamp tube).
3. Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃, 25%~95%RH.
(2) Belong to indoor stabilizer.
1. Input voltage(V): AC 110V.
2. Power frequency: 50 / 60 Hz.
3. Input power(W): 76.0W.
4. Input current(A): 0.7A.
5. Power factor: 99%.
6. Applicable lamp tube: T 8 – 4 0 W.