1. Protection function of electronic starter:
(1) Over-current protection.
(2) No-load protection (power consumption at no-load is less
than 1W).
(3) A florescent tube malfunction protection.
2. Safety requirement and reliability based:
(1) Life:
(a) Definition: the electronic starter fail to lid the lamp indicate
the end of life.
(2)Testing condition of life durability:
(a) Normal temperature test:25℃,test input voltage AC 110V, continue light for 50000Hrs.
(b) Low temperature test:0℃,test input voltage AC 110V, continue light for 360Hrs.
(c) High temperature test:80℃,test input voltage AC 110V, continue light for 360Hrs.
(d) Lid test:25℃,test input voltage AC 110V,apply 10000 cycle for 25sec on,35sec off/cycle(note: replace the failed lamp tube and continue the test again in case of break down of lamp tube).
3. Ambient condition for storage:
(1) Stowage condition: temperature -20℃~70℃、25%~95%RH.
(2) Belong to indoor stabilizer.
1. Model: BM–AFL0204.
2. T8 light tube suitable.
3. Nominal rated specification. (1) Input voltage(V): AC 110V. (2) Power frequency: 50 / 60 Hz. (3) Input power(W): 76.0W. (4) Input current(A): 0.7A. (5) Power factor: 99%. (6) Applicable lamp tube: T8–20W.